Voltage Ratio = Primary Turns / Secondary Turns
Par exemple :
Transformateur abaisseur
Input:
13.8kV
Output:
480V
The transformer reduces medium voltage electricity to a usable low voltage level for industrial equipment.
Three Phase Transformer Types
Three phase transformers can be classified according to construction, insulation method, cooling system, and application.
1. Three Phase Dry Type Transformer
A three phase dry type transformer uses air as the cooling and insulation medium instead of transformer oil.
Dry type transformers are widely used where fire safety and environmental protection are important.
Advantages of Dry Type Transformer
Haute sécurité incendie
Aucun risque de fuite d'huile
Peu d'entretien nécessaire
Convient à une installation en intérieur
Respectueux de l'environnement
Common Applications
Three phase dry type transformers are commonly installed in:
Bâtiments commerciaux
Hôpitaux
Aéroports
Centres de données
Installations industrielles
Centres commerciaux
Typical ratings:
| Capacité | Application |
|---|---|
| 15 kVA | Small commercial loads |
| 45 kVA | Industrial equipment |
| 75 kVA | Building power supply |
| 500 kVA | Factory distribution |
| 2500 kVA | Large industrial systems |
EverNew manufactures dry type transformers with:
- Copper winding
- Aluminum winding
- Cast resin insulation
- UL/CSA compliant designs

2. Three Phase Oil Immersed Transformer
A three phase oil immersed transformer uses insulating oil for cooling and electrical insulation.
Oil immersed transformers are commonly used for outdoor power distribution because they provide excellent heat dissipation and high capacity capability.
Avantages
- High power capacity
- Excellentes performances de refroidissement
- Longue durée de vie
- Suitable for outdoor applications
Applications
Common applications include:
- Sous-stations de services publics
- Fermes solaires
- Parcs éoliens
- Installations industrielles
- Power transmission systems
Typical voltage ratings:
- 6kV
- 10kV
- 11kV
- 13.8kV
- 35kV
- 110kV
- 220kV
3. Three Phase Distribution Transformer
A three phase distribution transformer is designed to reduce medium voltage electricity to low voltage for end users.
Typical conversion:
11kV → 400V
13.8kV → 480V
35kV → 400V
Applications :
- Zones résidentielles
- Commercial facilities
- Usines industrielles
4. Three Phase Power Transformer
A transformateur de puissance triphasé is used in high voltage transmission and substations.
Applications :
- Centrales électriques
- Grid substations
- Projets d'énergie renouvelable
Gamme de puissance :
From several MVA to hundreds of MVA.

Three Phase Transformer Applications
Systèmes d'alimentation industriels
Factories rely on three phase transformers to supply power for:
- Moteurs
- Compressors
- Pumps
- Machines à commande numérique
- Lignes de production
- Automation equipment
Industrial transformers usually require:
- Haute efficacité
- Fonctionnement continu
- Strong overload capability
Bâtiments commerciaux
Three phase transformers are commonly used in:
- Immeubles de bureaux
- Hôtels
- Centres commerciaux
- Aéroports
A common North American system:
480V → 208Y/120V
This voltage system is widely used for:
- Lighting
- Systèmes de chauffage, de ventilation et de climatisation
- Building equipment
Projets d'énergie renouvelable
Solar and wind projects require transformers to increase voltage before grid connection.
Exemple :
Solar inverter:
800V
↓
Transformer:
0.8kV / 35kV
↓
Grid connection
Three Phase Transformer Voltage Ratings
Different countries use different voltage standards.
Amérique du Nord
Common voltages:
| Tension primaire | Tension secondaire |
|---|---|
| 480V | 208Y/120V |
| 600V | 347/600V |
| 13.8kV | 480V |
| 34,5kV | 480V |
International Markets
Common systems:
| Primary | Secondary |
|---|---|
| 10kV | 400V |
| 11kV | 415V |
| 20kV | 400V |
| 35kV | 400V |
EverNew transformers can be designed according to:
- CEI
- ANSI
- IEEE
- UL
- CSA
- CE
- GOST

How To Select A Three Phase Transformer?
Pour choisir le transformateur adapté, il faut tenir compte de plusieurs paramètres techniques.
1. Transformer Capacity (kVA)
The transformer capacity must match the electrical load.
Common sizes:
- 15 kVA
- 30 kVA
- 45 kVA
- 75 kVA
- 112,5 kVA
- 150 kVA
- 500 kVA
- 1000 kVA
- 2500 kVA
2. Tension d'entrée et de sortie
Exemple :
Commercial building:
Input:
480V Three Phase
Output:
208Y/120V Three Phase
3. Frequency
Common frequencies:
- 50Hz
- 60Hz
4. Transformer Cooling Method
Choose according to installation environment:
Indoor:
Transformateur à sec
Outdoor:
Transformateur immergé dans l'huile
5. Transformer Standards
Les projets internationaux peuvent nécessiter :
- UL certification
- CSA certification
- DOE efficiency
- Normes CEI
- Normes IEEE

Three Phase Transformer Manufacturer
Selecting a reliable three phase transformer manufacturer is important for ensuring safety, efficiency, and long service life.
A professional transformer supplier should provide:
✔ Engineering design support
✔ Factory testing
✔ International certifications
✔ Customized voltage solutions
✔ Export experience
Why Choose EverNew Transformer?
EverNew Transformer is a professional transformer manufacturer in China with more than 30 years of experience.
Our manufacturing capabilities include:
Product Range
- Transformateur de distribution
- Transformateur à sec
- Transformateur immergé dans l'huile
- Transformateur sur socle
- Transformateur de puissance
Technical Capability
Capacité :
15 kVA – 500 MVA
Tension :
6kV – 500kV
Certifications
- UL
- CSA
- CE
- GOST
- ISO
We supply transformers for:
- ÉTATS-UNIS
- Canada
- Amérique du Sud
- L'Europe
- Asie
- Afrique
Three Phase Transformer FAQ
What is the difference between single phase and three phase transformer?
A single phase transformer is normally used for smaller loads, while a three phase transformer is designed for industrial and commercial power systems requiring higher capacity.
What is the most common three phase transformer voltage?
Common systems include:
- 480V
- 208Y/120V
- 400V
- 415V
- 13.8kV
- 35kV
How much does a three phase transformer cost?
Le prix dépend des éléments suivants :
- Transformer capacity
- Voltage rating
- Enroulement en cuivre ou en aluminium
- Méthode de refroidissement
- Normes obligatoires
- Order quantity
How do I choose a three phase transformer size?
You should consider:
- Total connected load
- Starting current
- Future expansion
- Exigences en matière de tension
- Efficiency requirements
Conclusion
A three phase transformer is an essential component in modern electrical power systems, providing efficient voltage conversion for industrial, commercial, and renewable energy applications.
Choosing the correct transformer requires careful evaluation of:
- Power capacity
- Voltage levels
- Méthode de refroidissement
- Environnement d'installation
- Normes internationales
En tant que professionnel three phase transformer manufacturer, EverNew Transformer provides reliable transformer solutions worldwide with customized designs from low voltage distribution systems to high voltage power networks.
Contact EverNew Transformer today for your three phase transformer project.