Voltage Ratio = Primary Turns / Secondary Turns
Zum Beispiel:
Abspanntransformator
Input:
13.8kV
Output:
480V
The transformer reduces medium voltage electricity to a usable low voltage level for industrial equipment.
Three Phase Transformer Types
Three phase transformers can be classified according to construction, insulation method, cooling system, and application.
1. Three Phase Dry Type Transformer
A three phase dry type transformer uses air as the cooling and insulation medium instead of transformer oil.
Dry type transformers are widely used where fire safety and environmental protection are important.
Advantages of Dry Type Transformer
Hohe Brandschutzsicherheit
No oil leakage risk
Geringer Wartungsaufwand
Geeignet für die Installation in Innenräumen
Umweltfreundlich
Common Applications
Three phase dry type transformers are commonly installed in:
Kommerzielle Gebäude
Krankenhäuser
Flughäfen
Datenzentren
Industrielle Einrichtungen
Einkaufszentren
Typical ratings:
| Kapazität | Anmeldung |
|---|---|
| 15 kVA | Small commercial loads |
| 45 kVA | Industrial equipment |
| 75 kVA | Building power supply |
| 500 kVA | Factory distribution |
| 2500 kVA | Large industrial systems |
EverNew manufactures dry type transformers with:
- Copper winding
- Aluminum winding
- Cast resin insulation
- UL/CSA compliant designs

2. Three Phase Oil Immersed Transformer
A three phase oil immersed transformer uses insulating oil for cooling and electrical insulation.
Oil immersed transformers are commonly used for outdoor power distribution because they provide excellent heat dissipation and high capacity capability.
Vorteile
- High power capacity
- Hervorragende Kühlleistung
- Lange Lebensdauer
- Suitable for outdoor applications
Anwendungen
Zu den gängigen Anwendungsbereichen gehören:
- Umspannwerke für Versorgungsunternehmen
- Solarparks
- Windparks
- Industrielle Anlagen
- Power transmission systems
Typical voltage ratings:
- 6kV
- 10kV
- 11kV
- 13.8kV
- 35 kV
- 110kV
- 220kV
3. Three Phase Distribution Transformer
A three phase distribution transformer is designed to reduce medium voltage electricity to low voltage for end users.
Typical conversion:
11kV → 400V
13.8kV → 480V
35kV → 400V
Anwendungen:
- Wohngebiete
- Commercial facilities
- Industrielle Fabriken
4. Three Phase Power Transformer
A Dreiphasen-Leistungstransformator is used in high voltage transmission and substations.
Anwendungen:
- Kraftwerke
- Grid substations
- Projekte für erneuerbare Energien
Leistungsbereich:
From several MVA to hundreds of MVA.

Three Phase Transformer Applications
Industrielle Energiesysteme
Factories rely on three phase transformers to supply power for:
- Motoren
- Compressors
- Pumps
- CNC-Maschinen
- Fertigungslinien
- Automation equipment
Industrial transformers usually require:
- Hoher Wirkungsgrad
- Kontinuierlicher Betrieb
- Strong overload capability
Kommerzielle Gebäude
Three phase transformers are commonly used in:
- Bürogebäude
- Hotels
- Einkaufszentren
- Flughäfen
A common North American system:
480V → 208Y/120V
This voltage system is widely used for:
- Lighting
- Klimaanlagen
- Building equipment
Projekte für erneuerbare Energien
Solar and wind projects require transformers to increase voltage before grid connection.
Beispiel:
Solar inverter:
800V
↓
Transformer:
0.8kV / 35kV
↓
Grid connection
Three Phase Transformer Voltage Ratings
Different countries use different voltage standards.
Nord-Amerika
Common voltages:
| Primäre Spannung | Sekundäre Spannung |
|---|---|
| 480V | 208Y/120V |
| 600V | 347/600V |
| 13.8kV | 480V |
| 34,5 kV | 480V |
International Markets
Common systems:
| Primary | Secondary |
|---|---|
| 10kV | 400V |
| 11kV | 415V |
| 20kV | 400V |
| 35 kV | 400V |
EverNew transformers can be designed according to:
- IEC
- ANSI
- IEEE
- UL
- CSA
- CE
- GOST

How To Select A Three Phase Transformer?
Um den richtigen Transformator auszuwählen, müssen mehrere technische Parameter berücksichtigt werden.
1. Transformer Capacity (kVA)
The transformer capacity must match the electrical load.
Common sizes:
- 15 kVA
- 30 kVA
- 45 kVA
- 75 kVA
- 112,5 kVA
- 150 kVA
- 500 kVA
- 1000 kVA
- 2500 kVA
2. Eingangs- und Ausgangsspannung
Beispiel:
Commercial building:
Input:
480V Three Phase
Output:
208Y/120V Three Phase
3. Frequency
Common frequencies:
- 50Hz
- 60Hz
4. Transformer Cooling Method
Choose according to installation environment:
Indoor:
Trockentransformator
Outdoor:
Ölgefüllter Transformator
5. Transformer Standards
Für internationale Projekte kann Folgendes erforderlich sein:
- UL certification
- CSA certification
- DOE efficiency
- IEC-Normen
- IEEE-Normen

Three Phase Transformer Manufacturer
Selecting a reliable three phase transformer manufacturer is important for ensuring safety, efficiency, and long service life.
A professional transformer supplier should provide:
✔ Engineering design support
✔ Factory testing
✔ International certifications
✔ Customized voltage solutions
✔ Export experience
Warum sollten Sie sich für EverNew Transformer entscheiden?
EverNew Transformer is a professional transformer manufacturer in China with more than 30 years of experience.
Zu unseren Fertigungskapazitäten gehören:
Product Range
- Verteilertransformator
- Trockentransformator
- Ölgefüllter Transformator
- Transformator für Pad-Montage
- Leistungstransformator
Technical Capability
Kapazität:
15 kVA – 500 MVA
Spannung:
6kV – 500kV
Zertifizierungen
- UL
- CSA
- CE
- GOST
- ISO
We supply transformers for:
- USA
- Kanada
- Südamerika
- Europa
- Asien
- Afrika
Three Phase Transformer FAQ
What is the difference between single phase and three phase transformer?
A single phase transformer is normally used for smaller loads, while a three phase transformer is designed for industrial and commercial power systems requiring higher capacity.
What is the most common three phase transformer voltage?
Common systems include:
- 480V
- 208Y/120V
- 400V
- 415V
- 13.8kV
- 35 kV
How much does a three phase transformer cost?
The price depends on:
- Transformer capacity
- Voltage rating
- Kupfer- oder Aluminiumwicklung
- Methode der Kühlung
- Required standards
- Order quantity
How do I choose a three phase transformer size?
You should consider:
- Total connected load
- Starting current
- Future expansion
- Spannungsanforderungen
- Efficiency requirements
Schlussfolgerung
A three phase transformer is an essential component in modern electrical power systems, providing efficient voltage conversion for industrial, commercial, and renewable energy applications.
Choosing the correct transformer requires careful evaluation of:
- Power capacity
- Voltage levels
- Methode der Kühlung
- Installationsumgebung
- Internationale Normen
Als Fachmann three phase transformer manufacturer, EverNew Transformer provides reliable transformer solutions worldwide with customized designs from low voltage distribution systems to high voltage power networks.
Contact EverNew Transformer today for your three phase transformer project.