Three Phase Transformer: Working Principle, Types, Applications and Selection Guide

Three Phase Power Transformer Guide with Types, Applications and Complete Transformer Solutions for Industrial and Utility Systems

Introdução

A three phase transformer is one of the most widely used electrical transformers in industrial power distribution systems. It is designed to transfer electrical energy between three-phase power circuits while changing voltage levels efficiently and safely.

Three phase transformers are commonly used in:

  • Fábricas industriais
  • Edifícios comerciais
  • Subestações de serviços públicos
  • Usinas de energia solar
  • Projetos de energia eólica
  • Mining facilities
  • Centros de dados
  • Manufacturing plants

Compared with single phase transformers, a three phase transformer provides higher power capacity, improved efficiency, and better load balance, making it the preferred solution for medium voltage and high-power electrical systems.

As an experienced three phase transformer manufacturer, EverNew Transformer provides customized transformer solutions from 15 kVA a 500 MVAincluindo:


What Is a Three Phase Transformer?

A three phase transformer is an electrical transformer designed for three-phase alternating current (AC) systems.

Unlike a single phase transformer, which operates with one alternating voltage waveform, a three-phase transformer uses three separate phases with a 120-degree phase difference.

The three phases provide:

  • Higher power transmission efficiency
  • Reduced conductor size
  • Better motor performance
  • More stable industrial power supply

A typical three phase transformer contains:

  • Three primary windings
  • Three secondary windings
  • Núcleo magnético
  • Sistema de isolamento
  • Sistema de resfriamento
  • Transformer enclosure

Three Phase Oil Immersed Transformer for Industrial Power Distribution Systems and Utility Substation Applications


How Does a Three Phase Transformer Work?

The operating principle of a three phase transformer is based on electromagnetic induction.

When AC voltage is applied to the primary winding, it creates alternating magnetic flux inside the transformer core. This magnetic flux induces voltage in the secondary winding.

The voltage conversion ratio depends on the relationship between winding turns:

Voltage Ratio = Primary Turns / Secondary Turns

Por exemplo:

Transformador abaixador

Input:

13.8kV

Output:

480V

The transformer reduces medium voltage electricity to a usable low voltage level for industrial equipment.

Three Phase Transformer Types

Three phase transformers can be classified according to construction, insulation method, cooling system, and application.

1. Three Phase Dry Type Transformer

A three phase dry type transformer uses air as the cooling and insulation medium instead of transformer oil.

Dry type transformers are widely used where fire safety and environmental protection are important.

Advantages of Dry Type Transformer
Alto nível de segurança contra incêndios
No oil leakage risk
Baixa necessidade de manutenção
Adequado para instalação em ambientes internos
Ecologicamente correto
Common Applications

Three phase dry type transformers are commonly installed in:

Edifícios comerciais
Hospitais
Aeroportos
Centros de dados
Instalações industriais
Shoppings

Typical ratings:

Capacidade Aplicativo
15 kVA Small commercial loads
45 kVA Industrial equipment
75 kVA Building power supply
500 kVA Factory distribution
2500 kVA Large industrial systems

EverNew manufactures dry type transformers with:

  • Copper winding
  • Aluminum winding
  • Cast resin insulation
  • UL/CSA compliant designs

Three Phase Dry Type Transformer Coil Manufacturing and Copper Winding Process for Industrial Power Transformer Production


2. Three Phase Oil Immersed Transformer

A three phase oil immersed transformer uses insulating oil for cooling and electrical insulation.

Oil immersed transformers are commonly used for outdoor power distribution because they provide excellent heat dissipation and high capacity capability.

Vantagens

  • High power capacity
  • Excelente desempenho de resfriamento
  • Longa vida útil
  • Suitable for outdoor applications

Aplicativos

Entre as aplicações mais comuns estão:

  • Subestações de serviços públicos
  • Fazendas solares
  • Parques eólicos
  • Instalações industriais
  • Power transmission systems

Typical voltage ratings:

  • 6kV
  • 10kV
  • 11kV
  • 13.8kV
  • 35kV
  • 110kV
  • 220kV

3. Three Phase Distribution Transformer

A three phase distribution transformer is designed to reduce medium voltage electricity to low voltage for end users.

Typical conversion:

11kV → 400V

13.8kV → 480V

35kV → 400V

Aplicativos:

  • Áreas residenciais
  • Commercial facilities
  • Fábricas industriais

4. Three Phase Power Transformer

A transformador trifásico de potência is used in high voltage transmission and substations.

Aplicativos:

  • Usinas de energia
  • Grid substations
  • Projetos de energia renovável

Faixa de potência:

From several MVA to hundreds of MVA.

High Quality Three Phase Transformer Winding Production Process with Copper Windings for Industrial Power Transformer Manufacturing


Three Phase Transformer Applications

Sistemas de energia industrial

Factories rely on three phase transformers to supply power for:

  • Motores
  • Compressors
  • Pumps
  • Máquinas CNC
  • Linhas de produção
  • Automation equipment

Industrial transformers usually require:

  • Alta eficiência
  • Operação contínua
  • Strong overload capability

Edifícios comerciais

Three phase transformers are commonly used in:

  • Edifícios comerciais
  • Hotéis
  • Shopping centers
  • Aeroportos

A common North American system:

480V → 208Y/120V

This voltage system is widely used for:

  • Lighting
  • Sistemas de climatização
  • Building equipment

Projetos de energia renovável

Solar and wind projects require transformers to increase voltage before grid connection.

Exemplo:

Solar inverter:

800V

Transformer:

0.8kV / 35kV

Grid connection


Three Phase Transformer Voltage Ratings

Different countries use different voltage standards.

América do Norte

Common voltages:

Tensão primária Tensão secundária
480V 208Y/120V
600V 347/600V
13.8kV 480V
34,5kV 480V

International Markets

Common systems:

Primary Secondary
10kV 400V
11kV 415V
20kV 400V
35kV 400V

EverNew transformers can be designed according to:

  • IEC
  • ANSI
  • IEEE
  • UL
  • CSA
  • CE
  • GOST

Three Phase Transformer Manufacturing Process in Modern Transformer Factory with Advanced Production Technology


How To Select A Three Phase Transformer?

A escolha do transformador correto exige a avaliação de vários parâmetros técnicos.


1. Transformer Capacity (kVA)

The transformer capacity must match the electrical load.

Common sizes:

  • 15 kVA
  • 30 kVA
  • 45 kVA
  • 75 kVA
  • 112,5 kVA
  • 150 kVA
  • 500 kVA
  • 1000 kVA
  • 2500 kVA

2. Tensão de entrada e saída

Exemplo:

Commercial building:

Input:

480V Three Phase

Output:

208Y/120V Three Phase


3. Frequency

Common frequencies:

  • 50Hz
  • 60Hz

4. Transformer Cooling Method

Choose according to installation environment:

Indoor:

Transformador do tipo seco

Outdoor:

Transformador imerso em óleo


5. Transformer Standards

Os projetos internacionais podem exigir:

  • UL certification
  • CSA certification
  • DOE efficiency
  • Normas IEC
  • Normas do IEEE

Outdoor Three Phase Pad Mounted Distribution Transformer for Utility Substation and Renewable Energy Power Projects


Three Phase Transformer Manufacturer

Selecting a reliable three phase transformer manufacturer is important for ensuring safety, efficiency, and long service life.

A professional transformer supplier should provide:

✔ Engineering design support

✔ Factory testing

✔ International certifications

✔ Customized voltage solutions

✔ Export experience


Por que escolher o transformador EverNew?

EverNew Transformer is a professional transformer manufacturer in China with more than 30 years of experience.

Nossas capacidades de fabricação incluem:

Product Range

  • Transformador de distribuição
  • Transformador do tipo seco
  • Transformador imerso em óleo
  • Transformador montado em bloco
  • Transformador de potência

Technical Capability

Capacidade:

15 kVA – 500 MVA

Tensão:

6kV – 500kV

Certificações

  • UL
  • CSA
  • CE
  • GOST
  • ISO

We supply transformers for:

  • EUA
  • Canadá
  • América do Sul
  • Europa
  • Ásia
  • África

Three Phase Transformer FAQ

What is the difference between single phase and three phase transformer?

A single phase transformer is normally used for smaller loads, while a three phase transformer is designed for industrial and commercial power systems requiring higher capacity.


What is the most common three phase transformer voltage?

Common systems include:

  • 480V
  • 208Y/120V
  • 400V
  • 415V
  • 13.8kV
  • 35kV

How much does a three phase transformer cost?

The price depends on:

  • Transformer capacity
  • Voltage rating
  • Enrolamento de cobre ou alumínio
  • Método de resfriamento
  • Required standards
  • Order quantity

How do I choose a three phase transformer size?

You should consider:

  • Total connected load
  • Starting current
  • Future expansion
  • Requisitos de tensão
  • Efficiency requirements

Conclusão

A three phase transformer is an essential component in modern electrical power systems, providing efficient voltage conversion for industrial, commercial, and renewable energy applications.

Choosing the correct transformer requires careful evaluation of:

  • Power capacity
  • Voltage levels
  • Método de resfriamento
  • Ambiente de instalação
  • Padrões internacionais

Como profissional three phase transformer manufacturer, EverNew Transformer provides reliable transformer solutions worldwide with customized designs from low voltage distribution systems to high voltage power networks.

Contact EverNew Transformer today for your three phase transformer project.

    Deixe um comentário