Three Phase Pole Mounted Transformer: Complete Guide to Sizes, Voltage, Price & Specifications

Three phase pole mounted transformer complete guide covering common kVA sizes, voltage ratings, technical specifications, applications and price factors

A three phase pole mounted transformer is an outdoor distribution transformer designed to convert medium-voltage electricity into lower three-phase voltage for utility, commercial, agricultural, and industrial applications.

Unlike pad-mounted transformers installed at ground level, a 3 phase pole mounted transformer is installed on utility poles and connected directly to overhead distribution lines. This makes it especially suitable for rural electrification, utility distribution networks, farms, industrial facilities, and locations where ground space is limited.

Three phase pole mounted transformers are available in a wide range of capacities and voltage ratings. Common sizes include 75 kVA, 100 kVA, 150 kVA, 167 kVA, 225 kVA, 300 kVA, and 500 kVA, with customized designs available according to different utility standards.

This guide explains the common sizes, voltage ratings, specifications, applications, prices, and selection considerations for three phase pole mounted transformers.

What Is a Three Phase Pole Mounted Transformer?

A three phase pole mounted transformer is generally an 유입식 배전 변압기 installed outdoors on a single-pole or multi-pole support structure.

Its main function is to step down medium-voltage distribution power, such as:

  • 11 kV → 400/230 V
  • 12.47 kV → 208Y/120 V
  • 12.47 kV → 480Y/277 V
  • 13.2 kV → 480Y/277 V
  • 13.8 kV → 220Y/127 V
  • 13.8 kV → 480Y/277 V
  • 24.9 kV → 480Y/277 V
  • 34.5 kV → 480Y/277 V

The exact voltage combination depends on the local utility network and project requirements.

Most pole mounted distribution transformers use ONAN(오일 내추럴 에어 내추럴) cooling and can be manufactured with either copper or aluminum windings.

Three phase pole mounted transformer manufacturing in China factory with oil immersed distribution transformers for utility and industrial overhead power networks

Common Three Phase Pole Mounted Transformer Sizes

Transformer capacity is normally expressed in kVA. The correct rating depends on the connected load, expected demand, future expansion, and utility requirements.

TRANSFORMER SIZE TYPICAL APPLICATIONS
45–75 kVA Farms, small commercial loads, rural distribution
100 kVA Commercial buildings and community distribution
150 kVA Commercial and light industrial applications
167 kVA Utility, commercial and industrial distribution
225 kVA 산업 및 상업 시설
300 kVA Factories and larger distribution loads
500 kVA Industrial and utility distribution
750 kVA+ Specialized high-capacity overhead applications

Larger transformers require careful consideration of the total transformer weight, pole structure, installation method, and local utility requirements.

For some high-capacity applications, a 패드 장착 변압기 or ground-mounted transformer may be more suitable.

167 kVA Three Phase Pole Mounted Transformer

그리고 167kVA 변압기 is an interesting capacity for utility and distribution applications and can be manufactured as a three-phase pole mounted transformer according to the required electrical system.

일반적인 167 kVA three phase pole mounted transformer may have specifications such as:

PARAMETER TYPICAL SPECIFICATION
정격 용량 167 kVA
단계 세 단계
기본 전압 12.47 kV / 13.2 kV / 13.8 kV
2차 전압 208Y/120 V / 220Y/127 V / 480Y/277 V
빈도 50Hz / 60Hz
와인딩 재료 구리 또는 알루미늄
냉각 ONAN
설치 Outdoor Pole Mounted
절연 매체 Mineral Oil or Alternative Fluid
탭 체인저 Off-Circuit
표준 ANSI / IEEE / IEC / CSA as required

For example, a project may require a 167 kVA transformer, 13.8 kV primary and 480Y/277 V secondary, 60 Hz, three phase, copper winding and ONAN cooling.

However, specifying only “167 kVA transformer” is not sufficient for manufacturing. Primary voltage, secondary voltage, phase, frequency, winding material, connection, BIL, applicable standard, and installation conditions should also be provided.

Compact three phase pole mounted transformer with high voltage bushings, oil immersed design for overhead utility power distribution

Common Voltage Ratings

Three phase pole mounted transformers can be designed for different utility distribution systems.

기본 전압

Common primary voltage ratings include:

4.16 kV, 6.6 kV, 10 kV, 11 kV, 12.47 kV, 13.2 kV, 13.8 kV, 22 kV, 24.9 kV, 33 kV and 34.5 kV.

2차 전압

Common secondary voltage ratings include:

208Y/120 V, 220Y/127 V, 380Y/220 V, 400Y/230 V, 415Y/240 V and 480Y/277 V.

Custom voltage combinations can also be manufactured according to the grid and end-user requirements.

Key Technical Specifications

When purchasing a three phase pole mounted transformer, several specifications should be confirmed.

Copper or Aluminum Windings

Both copper and aluminum are widely used for distribution transformer windings.

Copper windings provide high electrical conductivity and good mechanical strength, while aluminum windings can offer a more economical and lighter solution.

The winding material should be clearly specified in the RFQ.

냉각 방법

Most oil-immersed pole mounted transformers use ONAN cooling. Natural circulation of insulating oil transfers heat from the windings and core to the tank, where it is dissipated into the surrounding air.

탭 체인저

An off-circuit tap changer is commonly provided to compensate for variations in the incoming voltage.

A typical tap range is:

±2 × 2.5%

Other tap configurations can be provided according to utility specifications.

연결

Common transformer connections include Delta-Wye, Wye-Wye and Delta-Delta.

예를 들어:

Primary: 13.8 kV Delta
Secondary: 480Y/277 V Grounded Wye

IEC projects may instead specify vector groups such as Dyn11, Dyn1 or Yyn0.

BIL

For ANSI/IEEE projects, the Basic Impulse Insulation Level (BIL) is an important specification.

The required BIL depends on the system voltage and utility standard. It should be confirmed before the transformer design is finalized.

Three phase pole mounted transformer for overhead power distribution with compact oil immersed design for utility, industrial and rural electrical networks

Applications of Three Phase Pole Mounted Transformers

Three phase pole mounted transformers are widely used in:

  • 유틸리티 배포 네트워크
  • 농촌 전기화
  • 상업용 건물
  • Farms and agricultural facilities
  • Irrigation and pumping stations
  • Industrial workshops
  • Manufacturing facilities
  • 광산 개발 사업
  • 주거 단지
  • 공공 인프라
  • 재생에너지 프로젝트

They are particularly useful where the electrical distribution network uses overhead medium-voltage lines.

Three Phase vs Single Phase Pole Mounted Transformer

A 단상 극 장착 변압기 is commonly used for residential and small rural loads, while a three phase pole mounted transformer is better suited for larger commercial and industrial loads.

FEATURE SINGLE PHASE THREE PHASE
Electrical Supply 단상 세 단계
Typical Loads Residential, small rural Commercial, industrial
Motor Applications 제한적 Well suited
용량 Usually smaller Usually larger
건설 Simpler More complex

For facilities operating three-phase motors, pumps, HVAC equipment, or industrial machinery, a three phase transformer is generally the appropriate solution.

Pole Mounted Transformer vs Pad Mounted Transformer

The main difference is the installation method.

A 폴 장착형 변압기 is installed above ground and normally connected to overhead distribution lines.

A 패드 장착 변압기 is installed on a concrete foundation and is commonly connected to underground distribution cables.

Pole mounted transformers are particularly suitable when:

  • The existing network uses overhead lines
  • Ground space is limited
  • A simple utility distribution arrangement is required

Pad mounted transformers are generally preferred for underground distribution systems, commercial developments, residential communities, and applications requiring enclosed HV/LV compartments.

Three phase pole mounted transformer factory production line with multiple kVA sizes for utility, industrial and overhead power distribution systems

Three Phase Pole Mounted Transformer Price

그리고 three phase pole mounted transformer price varies significantly depending on the technical configuration.

The main cost factors include:

  • Transformer capacity (kVA)
  • 1차 및 2차 전압
  • 구리 또는 알루미늄 권선
  • Insulating fluid
  • BIL
  • Transformer losses and efficiency
  • Bushings and terminals
  • 탭 체인저
  • Surge arresters and protection
  • ANSI/IEEE, IEC or CSA requirements
  • 수량
  • Destination and shipping cost

For example, the price of a 75 kVA pole mounted transformer will be considerably different from a customized 167 kVA or 300 kVA three phase pole mounted transformer.

Similarly, a transformer designed for 13.8 kV / 480Y/277 V under ANSI/IEEE requirements may have a different cost from an IEC-designed 11 kV / 400 V transformer.

Therefore, an accurate transformer price should be based on the complete project specification rather than only the kVA rating.

How to Select a Three Phase Pole Mounted Transformer

Before requesting a quotation, confirm the following information:

정격 용량: 75 kVA, 100 kVA, 167 kVA, 225 kVA, 300 kVA, etc.
기본 전압: 11 kV, 12.47 kV, 13.8 kV, 24.9 kV, etc.
보조 전압: 208Y/120 V, 400/230 V, 480Y/277 V, etc.
빈도: 50Hz 또는 60Hz
와인딩 재질: 구리 또는 알루미늄
Connection: Delta/Wye or required vector group
설치: Outdoor Pole Mounted
Applicable Standard: ANSI/IEEE, IEC, CSA or local utility standard
환경 조건: Temperature, altitude and pollution level
Quantity and Destination: Required for production and freight calculation

Providing these parameters allows the transformer manufacturer to select the correct electrical design, insulation level, dimensions, weight, accessories, and price.

Read More:Single Phase Power Transformer: Complete Guide for Selection, Applications and Purchasing (2026)

Three phase pole mounted distribution transformers with ONAN cooling for utility, industrial and overhead power distribution systems

자주 묻는 질문

What sizes are available for three phase pole mounted transformers?

Common ratings include 45 kVA, 75 kVA, 100 kVA, 150 kVA, 167 kVA, 225 kVA, 300 kVA and 500 kVA. Other capacities can be customized.

Is a 167 kVA transformer available in three phase?

Yes. A 167kVA 변압기 can be designed as a three phase pole mounted distribution transformer. The primary voltage, secondary voltage, frequency, winding connection and applicable standard should be specified.

Can a pole mounted transformer have copper windings?

Yes. Three phase pole mounted transformers can be manufactured with either copper or aluminum windings.

What is the typical cooling method?

Most oil-immersed pole mounted transformers use ONAN(오일 내추럴 에어 내추럴) cooling.

What information is required for a quotation?

At minimum, provide the kVA rating, primary voltage, secondary voltage, phase, frequency, winding material, quantity, applicable standard and destination country.

Three Phase Pole Mounted Transformer Manufacturer

A reliable three phase pole mounted transformer should be designed according to the actual electrical network, load requirements, environmental conditions and applicable utility standards.

에버뉴 트랜스포머 manufactures customized power and distribution transformers for international utility, industrial, commercial and infrastructure projects. Our transformer range covers 6kV ~ 500kV, with solutions including three phase pole mounted transformers, single phase pole mounted transformers, pad mounted transformers, oil-immersed distribution transformers, dry type transformers and large power transformers.

Whether your project requires a 75 kVA, 100 kVA, 167 kVA, 225 kVA, 300 kVA or 500 kVA three phase pole mounted transformer, the voltage, winding material, connection, frequency and accessories can be customized according to project requirements.

For a quotation, send us your required kVA, primary and secondary voltage, frequency, winding material, quantity and destination.

Evernew Transformer – Professional Power & Distribution Transformer Manufacturer in China

    답글 남기기