Looking for reliable substation transformers? Look no further! At Evernew Transformer, we specialize in manufacturing high-quality power transformers for substations. As leading substation transformer manufacturers, we ensure every product meets rigorous standards for performance and durability.
This 20000 kVA 33.5kV to 0.44kV substation transformer was launched by EverNew, the best substation transformer manufacturing company in China. Through early communication with technical personnel, the product design was quickly completed, and the product manufacturing and transformer factory testing were completed in 30 days. Through load, short circuit, temperature rise and other tests, all test indicators met the design standards.
Explore our range of substation transformer for sale, tailored to meet the evolving needs of modern power grids. Contact us today to learn more about our competitive substation transformer price and how Evernew Transformer can optimize your power distribution solutions.
Explore more Power Transformers: 63kv 66kv 69kv High Voltage Power Transformer Manufacturer
Routine Factory Tests For Substation Transformer
Our transformers are designed to optimize power distribution in diverse environments, from industrial facilities to utility grids. Each unit undergoes meticulous testing to guarantee reliability and efficiency. Whether you need a copper substation transformer or are exploring substation transformer for sale, Evernew Transformer offers competitive prices without compromising quality.
- Ratio Test: Verification of the transformer’s input-to-output voltage ratio.
- Vector Group Test: Confirmation of the correct connection group for the transformer.
- DC Resistance Test: Measurement of the direct current resistance in the main circuit of the transformer.
- No-load Test: Measurement of power losses and current under no-load conditions.
- Load Test: Evaluation of efficiency and thermal stability at rated load.
- Capacity Test: Confirmation of the transformer’s rated capacity.
- Power Frequency Withstand Voltage Test: Detection of insulation strength between windings and between winding and ground.
- Induced Voltage Withstand Test: Validation of withstand voltage capability between windings and magnetic circuit.
- Insulation Resistance Test: Assessment of insulation resistance to ensure long-term stability.
- Dielectric Loss Test: Measurement of dielectric losses in transformer windings, reflecting insulation quality.
- Partial Discharge Test: Detection of partial discharge within transformer windings to assess insulation health.
- Impulse Voltage Test: Application of high-voltage impulses to evaluate insulation withstand capability.
These comprehensive tests are critical during transformer production to ensure safe and reliable operation during installation and throughout its operational life, meeting diverse application and environmental requirements.
Explore our range today and discover why customers trust us for their critical power needs. Contact us for more information on substation transformer prices and specifications. Trust Evernew Transformer for top-notch solutions in transformer and substation technology!
CONTACT EVERNEW TEAMManufacturing of 20000 kVA 33.5kV to 0.44kV substation transformer
Technical Characteristics of 20000 KVA 33.5KV to 0.44KV Substation Transformer
Place of Origin | China |
---|---|
Brand Name | EverNew Transformer |
Model Number | Oil immersed transformer |
Number of Phase | Three Phase |
Coil Number | Three |
Use | power |
Winding Type | Two Winding |
Coil Structure | layer coil |
Standard | IEC ANSI IEEE |
Rated Capacity | 20000 KVA |
High Voltage | 34.5kV |
Impedance Voltage | 0.44KV |
Frequency | 50/60Hz |
Connection Group | Dyn11/Yyn0/Yd11/YNd11 |
Cooling Method | ONAN |
Coil Material | 100%Copper |